LoopConditionNotUpdatedInsideLoopInspection: serialization compatibility fixed

Review ID: IDEA-CR-28557
This commit is contained in:
Tagir Valeev
2018-01-19 17:00:01 +07:00
parent a1f0fee7e5
commit 355a550e6d
@@ -23,6 +23,7 @@ import com.siyeh.InspectionGadgetsBundle;
import com.siyeh.ig.BaseInspection;
import com.siyeh.ig.BaseInspectionVisitor;
import com.siyeh.ig.psiutils.*;
import org.jdom.Element;
import org.jetbrains.annotations.NotNull;
import org.jetbrains.annotations.Nullable;
@@ -34,6 +35,10 @@ public class LoopConditionNotUpdatedInsideLoopInspection extends BaseInspection
@SuppressWarnings({"PublicField"})
public boolean ignorePossibleNonLocalChanges = true;
// Preserved for serialization compatibility
@SuppressWarnings("unused")
public boolean ignoreIterators = false;
@Override
@NotNull
public String getDisplayName() {
@@ -53,6 +58,12 @@ public class LoopConditionNotUpdatedInsideLoopInspection extends BaseInspection
}
}
@Override
public void writeSettings(@NotNull Element node) {
defaultWriteSettings(node, "ignorePossibleNonLocalChanges");
writeBooleanOption(node, "ignorePossibleNonLocalChanges", true);
}
@Override
@Nullable
public JComponent createOptionsPanel() {